RESET FACTORY JUNIPER EX For Junos versions prior to 11.1, The recommendation is to use one of the following methods to return EX2200 to factory-defaults: Execute the following commands: lab@EX2200> request system configuration rescue delete lab@EX2200> start shell user root Password: root@EX2200% cd /config root@EX2200% rm -rf juniper.conf* root@EX2200% cd /config/db/config root@EX2200% rm -rf juniper.conf.* root@EX2200% reboot